Reservoir-Mounted Emergency Shower And Eyewash Station
The Reservoir-Mounted Emergency Shower and Eyewash Station combines a stainless steel water tank, overhead shower, eyewash assembly and modular support frame. Its elevated reservoir supplies flushing water by gravity, providing an independent water source for industrial sites without permanent water connections. Available in 350 L, 750 L and 1200 L capacities, the system supports different installation and project requirements.
Key Features
Gravity-Fed Water Supply
Uses stored water and natural gravity for flushing, without an electrically driven supply pump.
Multiple Tank Capacities
Three standard capacities support different water storage requirements and site configurations.
Corrosion-Resistant Materials
The tank and flushing heads use 304 stainless steel, while the support frame uses galvanized steel.
Modular Construction
The knock-down frame supports flat-pack transportation and convenient on-site assembly.
Technical Specifications
|
Parameter |
Specification |
|
Product Type |
Reservoir-Mounted Shower and Eyewash |
|
Water Supply |
Gravity-Fed |
|
Tank Capacity |
350 L / 750 L / 1200 L |
|
Tank Material |
Stainless Steel 304 |
|
Shower Head |
Stainless Steel 304 |
|
Eyewash Head |
Stainless Steel 304 |
|
Frame Material |
Galvanized Steel |
|
Shower Configuration |
Overhead Shower |
|
Eyewash Configuration |
Integrated Eyewash |
|
Frame Structure |
Modular |
|
Pump Requirement |
No Electric Supply Pump |
|
Packaging |
Flat-Pack |
Water Supply and Flushing Performance
Gravity Supply
Tank elevation and outlet positioning determine the available hydraulic head and water discharge performance.
Water Capacity
Tank selection must consider shower and eyewash flow rates, simultaneous operation and required flushing duration.
Temperature Control
Insulation and heating options can be configured according to ambient temperature and site operating conditions.
Applications
Chemical Processing
For emergency flushing stations near chemical storage, transfer and processing areas.
Oil and Gas Facilities
Suitable for remote operating areas and industrial installations requiring independent water storage.
Mining Operations
Applicable to mining sites, mineral processing facilities and remote working locations.
Manufacturing Plants
Suitable for production areas involving chemical handling, surface treatment and material preparation.
Customization Options
Tank Capacity
Standard options include 350 L, 750 L and 1200 L. Other capacities can be evaluated according to water demand.
Material Selection
Tank and component materials can be specified according to water quality and operating conditions.
Frame Structure
Support height, dimensions, mounting positions and structural arrangements can be adjusted to project drawings.
Temperature Protection
Insulation, electric heating and temperature monitoring can be configured for different climates.
Quality Control and Testing
Material Inspection: Stainless steel grades, material thickness and galvanized frame components are checked against specifications.
Fabrication Inspection: Tank dimensions, weld seams, surface finish and frame connections are inspected during production.
Functional Testing: Shower heads, eyewash components, valves and water connections are checked. Water discharge and spray distribution are evaluated against the selected configuration before shipment.
Installation and Project Requirements
Foundation Requirements: The foundation must support the filled tank and complete equipment structure. Anchoring positions should be confirmed before installation.
Installation Height: Tank elevation and outlet positioning must provide the hydraulic head required for gravity-fed operation.
Assembly and Commissioning: Components are assembled according to installation drawings. Tank filling, leakage checks and functional flow tests should be completed before commissioning.
Standards and Technical Documentation
ANSI/ISEA Z358.1
Equipment performance can be evaluated against applicable requirements for emergency shower and eyewash flow, flushing duration, temperature and installation.
EN 15154
EN 15154-5:2019 provides relevant requirements for industrial emergency body showers equipped with storage tanks. Applicable eyewash requirements should be assessed separately.
Technical Documentation
Available documents include:
- Product technical datasheets
- General arrangement drawings
- Material specifications
- Installation instructions
- Inspection and testing records
- Operation and maintenance instructions
Frequently Asked Questions
Q: What tank capacities are available?
A: Standard capacities are 350 L, 750 L and 1200 L. Other capacities can be evaluated according to project requirements.
Q: Can the station operate without mains water?
A: Yes. The gravity-fed system uses stored water and does not require a permanent water connection during operation. The tank must be filled before use.
Q: Can the shower and eyewash operate simultaneously?
A: Yes, subject to hydraulic configuration and verification of combined flow rates and available flushing duration.
Q: Is the station suitable for outdoor installation?
A: Yes. Insulation and heating options can be specified according to local climate and installation conditions.
Q: Can the equipment be customized?
A: Yes. Tank capacity, frame dimensions, materials, connections and temperature-control arrangements can be customized according to project specifications.
Hot Tags: reservoir-mounted emergency shower and eyewash station, China reservoir-mounted emergency shower and eyewash station manufacturers, suppliers, factory, Freeze-Protected Shower and Eyewash Station
You Might Also Like