Reservoir-Mounted Emergency Shower And Eyewash Station

Reservoir-Mounted Emergency Shower And Eyewash Station

The Reservoir-Mounted Emergency Shower and Eyewash Station combines a stainless steel water tank, overhead shower, eyewash assembly and modular support frame.
Send Inquiry
Product Introduction

The Reservoir-Mounted Emergency Shower and Eyewash Station combines a stainless steel water tank, overhead shower, eyewash assembly and modular support frame. Its elevated reservoir supplies flushing water by gravity, providing an independent water source for industrial sites without permanent water connections. Available in 350 L, 750 L and 1200 L capacities, the system supports different installation and project requirements.

 

Key Features

 
01/

Gravity-Fed Water Supply
Uses stored water and natural gravity for flushing, without an electrically driven supply pump.

02/

Multiple Tank Capacities
Three standard capacities support different water storage requirements and site configurations.

03/

Corrosion-Resistant Materials
The tank and flushing heads use 304 stainless steel, while the support frame uses galvanized steel.

04/

Modular Construction
The knock-down frame supports flat-pack transportation and convenient on-site assembly.

Technical Specifications

 

 

Parameter

Specification

Product Type

Reservoir-Mounted Shower and Eyewash

Water Supply

Gravity-Fed

Tank Capacity

350 L / 750 L / 1200 L

Tank Material

Stainless Steel 304

Shower Head

Stainless Steel 304

Eyewash Head

Stainless Steel 304

Frame Material

Galvanized Steel

Shower Configuration

Overhead Shower

Eyewash Configuration

Integrated Eyewash

Frame Structure

Modular

Pump Requirement

No Electric Supply Pump

Packaging

Flat-Pack

 

Water Supply and Flushing Performance

 

Gravity Supply

Tank elevation and outlet positioning determine the available hydraulic head and water discharge performance.

Water Capacity

Tank selection must consider shower and eyewash flow rates, simultaneous operation and required flushing duration.

Temperature Control

Insulation and heating options can be configured according to ambient temperature and site operating conditions.

 

Applications

 

 

Chemical Processing
For emergency flushing stations near chemical storage, transfer and processing areas.
Oil and Gas Facilities
Suitable for remote operating areas and industrial installations requiring independent water storage.
Mining Operations
Applicable to mining sites, mineral processing facilities and remote working locations.
Manufacturing Plants
Suitable for production areas involving chemical handling, surface treatment and material preparation.

 

Customization Options

 

 

Tank Capacity
Standard options include 350 L, 750 L and 1200 L. Other capacities can be evaluated according to water demand.
Material Selection
Tank and component materials can be specified according to water quality and operating conditions.
Frame Structure
Support height, dimensions, mounting positions and structural arrangements can be adjusted to project drawings.
Temperature Protection
Insulation, electric heating and temperature monitoring can be configured for different climates.

 

Quality Control and Testing

 

 

Material Inspection: Stainless steel grades, material thickness and galvanized frame components are checked against specifications.


Fabrication Inspection: Tank dimensions, weld seams, surface finish and frame connections are inspected during production.


Functional Testing: Shower heads, eyewash components, valves and water connections are checked. Water discharge and spray distribution are evaluated against the selected configuration before shipment.

 

Installation and Project Requirements

 

 

Foundation Requirements: The foundation must support the filled tank and complete equipment structure. Anchoring positions should be confirmed before installation.


Installation Height: Tank elevation and outlet positioning must provide the hydraulic head required for gravity-fed operation.


Assembly and Commissioning: Components are assembled according to installation drawings. Tank filling, leakage checks and functional flow tests should be completed before commissioning.

 

Standards and Technical Documentation

 

 

ANSI/ISEA Z358.1
Equipment performance can be evaluated against applicable requirements for emergency shower and eyewash flow, flushing duration, temperature and installation.


EN 15154
EN 15154-5:2019 provides relevant requirements for industrial emergency body showers equipped with storage tanks. Applicable eyewash requirements should be assessed separately.


Technical Documentation
Available documents include:

  • Product technical datasheets
  • General arrangement drawings
  • Material specifications
  • Installation instructions
  • Inspection and testing records
  • Operation and maintenance instructions

 

Frequently Asked Questions

 

 

Q: What tank capacities are available?

A: Standard capacities are 350 L, 750 L and 1200 L. Other capacities can be evaluated according to project requirements.

Q: Can the station operate without mains water?

A: Yes. The gravity-fed system uses stored water and does not require a permanent water connection during operation. The tank must be filled before use.

Q: Can the shower and eyewash operate simultaneously?

A: Yes, subject to hydraulic configuration and verification of combined flow rates and available flushing duration.

Q: Is the station suitable for outdoor installation?

A: Yes. Insulation and heating options can be specified according to local climate and installation conditions.

Q: Can the equipment be customized?

A: Yes. Tank capacity, frame dimensions, materials, connections and temperature-control arrangements can be customized according to project specifications.