Enclosed Emergency Showers
Enclosed Emergency Showers Manufacturer & Supplier
Since 2007, we have focused on the research, development and manufacturing of emergency shower and eyewash equipment. Our 15+ R&D personnel and 300+ employees support product engineering, production and quality management. With 18+ years of industry experience, we supply enclosed emergency shower systems for industrial facilities worldwide, supported by technical consultation, project-specific configurations and coordinated export services.
Why Choose Us
Dedicated Product Expertise
We specialize in emergency shower and eyewash equipment. This product focus supports practical knowledge of shower assemblies, eyewash components, water supply arrangements and industrial installation requirements.
Integrated Production
Our operations cover product development, component processing, fabrication, assembly and quality inspection. CNC machining and metalworking equipment support the production of equipment components and structural parts.
Technical Specification Review
We review project requirements such as installation space, water pressure, drainage position, ambient temperature and material selection before confirming a configuration.
International Supply Support
We coordinate order specifications, production progress, protective packaging, export documentation and shipment arrangements for overseas customers.

Enclosed Washing Space
The enclosure defines the emergency washing area and helps contain splashing during operation. Its dimensions and access arrangement should allow users to enter and operate the equipment without obstruction.
Accessible Operation
Shower and eyewash controls are positioned for direct access. The selected operating valves should support hands-free flushing after activation.
Integrated Equipment Layout
The internal arrangement can accommodate the shower assembly, optional eyewash equipment and associated pipework. Component positions are reviewed against user access and maintenance needs.
Industrial Installation
The enclosure layout can be assessed for indoor or outdoor installation, taking account of available floor space, access routes, environmental exposure and utility connections.
Stainless Steel Enclosure
Stainless steel is used for the enclosure structure. The appropriate grade should be selected according to moisture levels, cleaning procedures and possible chemical exposure.
Surface Finish
Surface finish and fabrication details can be reviewed according to the installation environment and cleaning requirements. Material grade and finish should be stated in the approved order specification.
Structural Dimensions
Overall height, width, depth, door opening and internal clearance affect installation and user access. These dimensions should be confirmed against the available site space before production.
Floor and Access Design
Floor grating, entry arrangements and internal clearance should support stable access and allow flushing water to reach the drainage area.

Water Supply, Heating and Temperature Control
Water Inlet
The supply connection must provide the pressure and flow required by the selected shower and eyewash configuration. Inlet size, position and connection type should be confirmed during technical review.
Flushing Water Temperature
ANSI/ISEA Z358.1 identifies tepid flushing fluid as 16–38°C. Where incoming water falls outside the required range, a suitable temperature-control arrangement should be evaluated.
Heating Options
For installations requiring temperature control, available heating arrangements can be reviewed against the water supply, electrical conditions and expected operating temperature.
Freeze Protection
For cold-weather sites, insulation, electric heat tracing and other suitable freeze-protection arrangements should be assessed according to the minimum ambient temperature and installation conditions.
Shower and Eyewash System Configuration

Emergency Shower Assembly
The shower assembly provides full-body flushing. Selection should consider the required flow rate, spray pattern, showerhead position and available water supply.
Eyewash Assembly
The eyewash provides simultaneous flushing to both eyes. Nozzle arrangement, protective covers, flow pattern and operating controls should be checked against the applicable performance requirements.


Combined Water Supply
When shower and eyewash functions are installed together, the supply system must provide sufficient flow for simultaneous operation. Pipe sizing and available water pressure should be reviewed before installation.
Operating Valves
The activation arrangement should be easy to locate and operate. Once activated, the flushing valve should remain open without requiring the user to hold the control.

Drainage and Water Containment Design
Floor Water Collection
The floor arrangement directs flushing water toward the drainage outlet. Floor slope, collection area and outlet position should be considered during enclosure design.
Drain Connection
Drainage pipe size, outlet location and discharge direction must match the site's plumbing layout. The receiving drainage system should also be suitable for the expected wastewater.
Site Drainage Planning
Facilities handling hazardous chemicals should review wastewater collection and treatment requirements before connecting the unit to the site drainage network.
Maintenance Access
Drain connections and service components should remain accessible for inspection, cleaning and routine maintenance.
Technical Specifications and Available Configurations
|
Specification |
Reference Value |
|
Emergency Shower Flow Rate |
75.7 L/min |
|
Emergency Shower Flushing Duration |
15 min |
|
Eyewash Flow Rate |
1.5 L/min |
|
Eyewash Flushing Duration |
15 min |
|
Tepid Flushing Water Temperature |
16–38°C |
|
Eyewash Valve Activation Time |
1 second or less |
|
Enclosure Material |
Stainless Steel |
|
Enclosure Dimensions |
Project-Specific |
|
Water Supply |
Continuous Supply |
|
Installation Type |
Floor-Mounted |
Applications and Industries

Chemical Processing: For chemical production, storage and handling areas where workers may be exposed to corrosive substances, process chemicals or hazardous liquids.
Pharmaceutical Manufacturing: For production and preparation areas that handle cleaning agents, process chemicals and other materials requiring accessible emergency washing facilities.
Electronics Manufacturing: For facilities involving chemical cleaning, surface treatment and production processes with potential eye or skin exposure.
Laboratories: For industrial and testing laboratories where chemicals, reagents and liquid materials are handled during routine work.
Metal Processing: For surface treatment, metal finishing and mechanical production facilities requiring emergency washing equipment near relevant work areas.
Outdoor Industrial Facilities: For external installations where enclosure protection, water temperature, weather exposure and freeze protection need to be considered together.
Safety Standards and Compliance
ANSI/ISEA Z358.1
This standard provides performance criteria for emergency shower and eyewash equipment, including flushing flow, duration, water temperature, spray characteristics and operating controls. The selected product configuration should be evaluated against the applicable requirements.
CE Marking
CE marking and supporting conformity documentation should be checked for the specific product and configuration being supplied. Applicable documentation can be confirmed during order review.
Technical Documents
Product specifications, installation instructions, operating information and available conformity documents can be provided according to the selected equipment and destination market.
Customization and Project-Specific Solutions
Enclosure Dimensions
We can review project-specific enclosure dimensions, door openings and internal clearances according to the available installation space and access requirements.
01
Material Selection
Stainless steel grade, surface finish and component materials can be discussed according to site conditions, cleaning procedures and chemical exposure.
02
Functional Configuration
Shower and eyewash combinations, heating arrangements, drainage connections and internal equipment positions can be reviewed for the project.
03
Order Specification
Before production, we confirm the approved dimensions, materials, connections and functional requirements. This provides a clear specification for manufacturing and order inspection.
04
Incoming Material Inspection
Materials and purchased components are checked against the relevant specifications before production.
Component Processing
Machining, cutting, drilling and metal fabrication are carried out according to component drawings and production requirements.
Assembly Checks
Assembly inspection covers component positioning, pipe connections, structural workmanship and the installation of operating parts.
Final Inspection
Finished equipment is checked against the approved order specifications. Applicable dimensional, appearance, connection and functional checks are completed before packaging.

Packaging, Shipping and After-Sales Support
Protective Packaging
Packaging is selected according to enclosure dimensions, equipment structure and transportation requirements. Protective measures are arranged to help safeguard surfaces and components during handling and shipment.
Export Coordination
We coordinate packing details, shipping information, export documentation and order progress to support international delivery.
Installation and Operation Guidance
Technical support covers installation conditions, water and drainage connections, operating procedures and routine inspection requirements.
After-Sales Technical Support
We provide assistance with equipment operation and maintenance through telephone and video support, with on-site assistance available upon request. Warranty coverage follows the terms confirmed for the supplied product.
Frequently Asked Questions

Discuss Your Enclosed Shower Requirements
Send us your project dimensions, installation conditions, water supply details and required configuration. We will review the specifications, confirm suitable equipment options and coordinate the quotation, production, packaging and delivery arrangements.