Enclosed Emergency Shower And Eyewash Unit For Industrial Facilities

Enclosed Emergency Shower And Eyewash Unit For Industrial Facilities

The Enclosed Emergency Shower and Eyewash Unit combines a full-body emergency shower, eye/face wash assembly and stainless steel enclosure in one integrated safety installation.
Send Inquiry
Product Introduction

The Enclosed Emergency Shower and Eyewash Unit combines a full-body emergency shower, eye/face wash assembly and stainless steel enclosure in one integrated safety installation. It provides a designated flushing area for industrial facilities handling chemicals, corrosive liquids and process substances. The SS304 stainless steel enclosure incorporates shower and eyewash components with a water collection and drainage arrangement. The integrated configuration is suitable for chemical processing plants, pharmaceutical facilities, laboratories and electronics production areas requiring dedicated emergency washing equipment.

 

Key Features

 

 

Integrated Shower and Eye/Face Wash
The overhead shower and eye/face wash station provide body and eye flushing within one installation. Dedicated activation controls allow the two functions to be operated independently, with simultaneous operation supported by the specified system configuration.


SS304 Stainless Steel Enclosure
The enclosure uses SS304 stainless steel for its main structure. The metal surfaces provide a practical finish for industrial cleaning and routine equipment inspection.


Integrated Water Collection
The floor collection structure directs used flushing water toward the drainage outlet. This arrangement supports wastewater collection within the designated washing area.


Industrial Water Connections
The unit uses dedicated water supply and drainage connections. Connection specifications can be coordinated with the facility piping layout before installation.

 

Technical Specifications

 

 

Item

Specification

Product Type

Enclosed Emergency Shower and Eyewash

Main Enclosure Material

SS304 Stainless Steel

Shower Flow Rate

≥75.7 L/min

Eye/Face Wash Flow Rate

≥11.4 L/min

Working Pressure

30–80 psi

Water Inlet

1-1/4 inch FNPT

Drainage Outlet

1-1/4 inch FNPT

Shower Function

Full-Body Flushing

Eyewash Function

Eye/Face Flushing

Shower Control

Ball Valve

Assembly

Pre-Assembled

Inspection

Pressure Testing

 

Enclosure and System Configuration

 

 

Enclosure Structure
The stainless steel booth forms a designated emergency washing space. Panel arrangement, entrance dimensions and internal clearance can be specified according to the installation layout.


Shower Assembly
The overhead shower delivers a specified flow rate of at least 75.7 L/min. Its water supply and valve arrangement are selected according to the required operating conditions.


Eye/Face Wash Assembly
The integrated eye/face wash delivers at least 11.4 L/min. The bowl, spray nozzles and activation controls are arranged for accessible emergency operation.


Drainage System
The floor collection structure directs wastewater through the designated outlet. Drainage connection details are coordinated with the facility discharge system.

 

Industrial Applications

 

 

Chemical Processing Plants: For production and handling areas involving acids, alkalis, chemical solutions and corrosive process liquids.


Pharmaceutical Facilities: For manufacturing zones where chemical preparation, cleaning agents and liquid processing require emergency flushing equipment.


Laboratories: For testing and research areas handling chemical reagents and laboratory process substances.


Electronics Manufacturing: For production facilities requiring dedicated emergency washing equipment and controlled wastewater collection.


Industrial Production Areas: For surface treatment, equipment cleaning and other operations involving chemical handling.

 

Performance And Compliance Requirements

 

 

Shower Flow: The specified shower flow rate is at least 75.7 L/min. The facility water supply should maintain the required flow throughout emergency operation.


Eye/Face Wash Flow: The specified eye/face wash flow rate is at least 11.4 L/min. Spray distribution should be checked under the selected operating pressure.


Continuous Flushing: ANSI/ISEA Z358.1 specifies a minimum 15-minute flushing capability for applicable emergency shower and eye/face wash equipment. The water supply must support the required operating flow for the full duration.


Water Temperature: The standard defines tepid flushing fluid within 16–38°C. A suitable temperature-control arrangement should be included in the project water supply design.


Standard Review: Applicable performance requirements, test results and supporting documentation should be confirmed for the final equipment configuration.

 

Installation Requirements

 

 

Installation Space
Confirm enclosure dimensions, entrance clearance and access space using the approved technical drawing.
Water Supply
Provide a 1-1/4 inch FNPT inlet connection. Verify the available pressure and flow capacity against the specified operating requirements.
Drainage Connection
Prepare a 1-1/4 inch FNPT outlet and connect it to the designated wastewater discharge system.
Site Accessibility
Position the equipment on an accessible route close to the identified hazard area, with clear access and suitable emergency signage.

Customization Options

 

 

Enclosure Dimensions
Length, width, height and internal layout can be adjusted according to project drawings.
Material Selection
Stainless steel specifications can be reviewed according to chemical exposure and site operating conditions.
Structural Configuration
Entrance arrangements, panel layout, floor grating and drainage positions can be coordinated with the installation design.
Additional Equipment
Temperature-control systems, emergency alarms and electrical accessories can be specified according to project requirements.

 

Manufacturing and Quality Control

 

 

Material Inspection: Stainless steel specifications and incoming components are checked against the confirmed product configuration.


Fabrication and Assembly: Enclosure fabrication, welded joints, pipe connections, valve installation and component positioning are inspected during assembly.


Pressure Testing: The assembled water system undergoes pressure testing to inspect connections and verify system integrity.


Final Inspection: Assembly condition, connection details and operating functions are checked before packing. Technical and inspection documents can be prepared according to the confirmed order requirements.

 

Frequently Asked Questions

 

 

Q: Can the shower and eye/face wash operate simultaneously?

A: Yes. The system configuration can support simultaneous operation, provided the water supply meets the combined flow demand.

Q: What is the required water supply pressure?

A: The specified working pressure is 30–80 psi. Available flow and pressure should be verified at the equipment inlet.

Q: Can the enclosure dimensions be customized?

A: Yes. Overall dimensions, entrance arrangements and internal layout can be adjusted according to installation drawings.

Q: What drainage connection does the unit use?

A: The specified drainage outlet is 1-1/4 inch FNPT. The site discharge arrangement should be confirmed before installation.

Q: Can technical drawings and inspection documents be provided?

A: Yes. Technical drawings, connection details and available inspection records can be prepared according to the selected configuration.

Hot Tags: enclosed emergency shower and eyewash unit for industrial facilities, China enclosed emergency shower and eyewash unit for industrial facilities manufacturers, suppliers, factory, Safety Shower for Chemical Transfer Stations

Send Inquiry

Home