The Enclosed Emergency Shower and Eyewash Unit integrates an overhead emergency shower, an eyewash station and a protective enclosure into one industrial safety installation. It provides a dedicated flushing area for personnel exposed to chemicals, corrosive liquids and other hazardous substances.
The enclosed design helps contain splashing water during emergency use and incorporates a designated floor drainage area. The integrated layout brings body showering, eye flushing, water connections and access arrangements into one installation. Stainless steel construction and configurable enclosure dimensions allow the equipment to be specified according to facility layouts, operating conditions and project requirements.
Key Features
Combined Emergency Washing: Integrates body shower and eyewash functions in one station. The water supply can be configured to maintain the required flow when both functions operate simultaneously.
Enclosed Operating Space: Provides a dedicated flushing area with enclosure panels and a defined entrance. Internal clearance is planned around user access and emergency operation.
Stainless Steel Construction: SS304 and SS316 material options support different industrial environments. Material grades can be selected according to chemical exposure and site conditions.
Integrated Floor Drainage: A floor drainage arrangement collects flushing water and connects to the facility drainage system according to the installation layout.
Project-Specific Configuration: Enclosure dimensions, access design, water connections and optional safety equipment can be specified according to project drawings.
Technical Specifications
|
Parameter |
Specification |
|
Product Type |
Enclosed Combination Unit |
|
Enclosure Material |
SS304 |
|
Optional Material |
SS316 |
|
Shower Flow Rate |
≥75.7 L/min |
|
Shower Duration |
≥15 minutes |
|
Eyewash Flow Rate |
≥1.5 L/min |
|
Eyewash Duration |
≥15 minutes |
|
Combined Minimum Flow |
≥77.2 L/min |
|
Water Temperature |
16–38°C |
|
Shower Operation |
Lever Pull Handle |
|
Eyewash Operation |
Push Handle |
|
Enclosure Dimensions |
Width 1200 mm by Depth 1000 mm by Height 2300 mm |
|
Water Inlet |
1 inch NPT Female Thread |
|
Drain Outlet |
2 inch NPT Female Thread |
Enclosure Structure and Configuration
Enclosure Dimensions: Overall width, depth and height are determined by the available installation space, internal operating clearance and access requirements.
Entrance Arrangement: Entrance configurations can include open access, protective curtains or doors, depending on the required enclosure design.
Internal Component Layout: The shower head, eyewash assembly, operating controls and water piping are positioned for accessible operation and routine inspection.
Floor and Drainage: Floor grating, drainage outlet position and connection size are specified according to the flushing water collection arrangement and site drainage layout.
Shower and Eyewash Performance
Body Shower Flow: The overhead shower provides full-body flushing. A minimum flow of 75.7 L/min for 15 minutes is the ANSI/ISEA Z358.1 selection requirement. Spray distribution and shower head positioning must also be checked.
Eyewash Flow: The eyewash delivers controlled water flow to both eyes simultaneously. The standard eyewash selection requirement is at least 1.5 L/min for 15 minutes. Eye/face wash configurations require a separate flow specification.
Simultaneous Operation: The supply system must support both functions operating together. Inlet pressure, pipe diameter and available water capacity should be calculated against the combined demand.
Industrial Applications
Chemical Processing Plants
For chemical transfer, mixing, storage and processing areas where emergency body and eye flushing is required.
Laboratories and Testing Facilities
For work areas involving chemical preparation, sample testing and laboratory liquid handling.
Pharmaceutical Production
For production and processing environments requiring accessible emergency washing facilities.
Petrochemical and Manufacturing Facilities
For industrial operations involving process chemicals, corrosive liquids and hazardous material handling.
Materials and Construction
SS304 Stainless Steel: Suitable for general industrial enclosure and piping applications where SS304 is specified.
SS316 Stainless Steel: Available for applications requiring additional corrosion resistance based on chemical exposure and operating conditions.
Fabrication and Assembly: Enclosure panels, structural supports, joints and piping connections are specified according to material requirements and approved construction drawings.
Customization Options
Configurations can be adjusted to match installation conditions and project specifications.
|
Material Grade |
SS304 or SS316. |
|
Enclosure Size |
Customized width, depth and height. |
|
Entrance Design |
Open entrance, curtain or door arrangement. |
|
Pipe Connections |
Specified inlet and drainage dimensions. |
|
Temperature Protection |
Heating, insulation and freeze-protection options. |
|
Safety Accessories |
Audible alarms, visual indicators and monitoring devices. |
Installation and Project Requirements
Water Supply: Confirm available pressure, inlet dimensions, flow capacity and water temperature. The supply must maintain the required flow during simultaneous shower and eyewash operation.
Drainage Connection: Specify the drainage outlet position, pipe size and discharge route according to the facility drainage plan.
Installation Clearance: Check the enclosure footprint, entrance access, internal operating space and maintenance clearance against the installation drawings.
Safety Standards: Confirm equipment performance, accessibility, flushing duration, operating controls and water temperature against applicable local requirements and the relevant ANSI/ISEA Z358.1 or EN 15154 provisions.
Frequently Asked Questions
Q: What is an enclosed emergency shower and eyewash unit used for?
A: It provides emergency body and eye flushing within a designated enclosure in facilities handling chemicals and hazardous liquids.
Q: Can the shower and eyewash operate simultaneously?
A: Yes. The combination unit requires a water supply and piping system sized for the combined flow demand.
Q: Is SS316 stainless steel available?
A: SS316 can be specified for projects requiring additional corrosion resistance according to the operating environment.
Q: Can the enclosure dimensions be customized?
A: Yes. Width, depth, height, entrance arrangements and connection positions can be specified according to project drawings.
Q: Can heating and alarm systems be included?
A: Heating, insulation, freeze protection and audible or visual alarms can be included as optional configurations according to site conditions.
Q: What information is required for a quotation?
A: Provide the required enclosure dimensions, material grade, water pressure, flow requirements, inlet and drainage connections, installation environment and applicable standards.
Hot Tags: enclosed emergency shower and eyewash unit, China enclosed emergency shower and eyewash unit manufacturers, suppliers, factory, Safety Shower for Chemical Transfer Stations
You Might Also Like
Send Inquiry